OEM Air Movement Solutions

Single Inlet Centrifugal Blower (External Rotor Motor)

Direct-drive centrifugal blowers engineered with external rotor motors for compact spaces, quiet operation, and continuous duty air handling.

Single Inlet Centrifugal Blower with External Rotor Motor manufactured by Delco Fans Delco Fans since 1974 emblem
Engineering Overview

Compact Air Movement Solutions for Controlled OEM Duty

Delco Fans manufactures high-efficiency single inlet centrifugal blowers integrated with external rotor motor technology. Designed with a single-sided axial intake and spiral scroll discharge, these compact blower assemblies are specifically built for restricted space profiles where high static pressure and low aerodynamic turbulence are essential.

By mounting the motor rotor directly inside the impeller hub, mechanical efficiency is maximized while eliminating belt maintenance or external motor overhang. Each unit is constructed in-house at our plant in Thane, India, undergoing strict electrical and air performance testing to ensure long operational lifespan in demanding OEM machinery.

Technical Data

Technical Specifications & Operating Envelope

Delco single inlet blowers can be customized to match your exact system resistance curve, electrical supply, and ambient requirements.

Single Inlet Centrifugal Blower Specification Table
Parameter Standard Specification Range OEM Customization Capabilities
Motor Architecture AC External Rotor Motor / EC Brushless Motor Custom winding turns, 115V / 230V, 50Hz / 60Hz single & 3-phase
Impeller Type Forward Curved Metal / Plastic Impeller Wheel width, blade angle, dynamically balanced to ISO 1940 standard
Airflow Rate 150 CFM to 1,800 CFM (250 m³/h to 3,000 m³/h) Specific duty-point matching to duct & filter resistance
Static Pressure Up to 850 Pa (3.4 in. wg) Scroll geometry tuning for low-flow or high-pressure setups
Speed & Control 900 RPM – 2,800 RPM (Fixed or Variable) Voltage regulator, TRIAC speed control, 0-10V PWM input (EC)
Insulation & Protection Class B (130°C) / Class F (155°C), IP44 / IP54 Thermal overload protection (TOP), tropicalized varnish dipping
Housing Finish Galvanized Steel / Powder-Coated Sheet Metal Stainless steel, aluminum, custom mounting flange hole dimensions
Key Advantages

Why Engineers Specify Delco External Rotor Blowers

Built on over 50 years of electrical motor and air movement manufacturing experience.

Ultra-Compact Direct-Drive Construction

The external rotor motor resides entirely within the blower impeller, drastically saving axial depth for tight enclosures and HVAC cabinets.

Dynamic Balancing & Low Vibration

Every rotor and impeller is precision-balanced to minimize acoustic noise, shaft runout, and bearing stress during continuous 24/7 duty.

Focused Air Delivery

Single inlet geometry draws air cleanly from one directional intake, allowing efficient connection to ducts, filters, or dedicated intake grilles.

Superior Motor Heat Dissipation

Moving air passing through the impeller actively draws thermal energy away from the external rotor surface, maintaining lower coil temperatures.

Heavy-Duty Ball Bearings

Pre-lubricated, sealed precision ball bearings ensure reliable operation in high ambient conditions up to +60°C without re-greasing.

OEM Specific Customization

Tailored mounting brackets, lead lengths, harness connectors, and voltage configurations designed directly to OEM manufacturing drawings.

Industrial Applications

Proven Deployment Across Critical Equipment

Delco single inlet centrifugal blowers perform reliably in applications demanding stable air distribution against system backpressure.

HVAC and ventilation application icon

HVAC & Cleanroom Units

Ducted ventilation, fan coil units, heat recovery ventilators, air purifiers, and laminar flow hoods.

Electrical panels and enclosures application icon

Electrical & Control Cabinets

Forced-air heat exchange in high-density drive panels, UPS systems, and power distribution enclosures.

Medical equipment application icon

Medical & Laboratory Devices

Sterilizers, laboratory incubators, fume extraction units, and medical diagnostic equipment cooling.

Industrial automation application icon

Machinery & Processing Lines

Drying tunnels, packaging machines, printing press air supply, and continuous industrial exhaust systems.

E-E-A-T Quality Assurance

In-House Manufacturing & Testing Rigor

At Delco Fans Pvt. Ltd., quality control is embedded into every production stage to safeguard long-term operational performance for international B2B buyers.

01. Stator Winding & Varnish

Precision Copper Coils

Automatic high-density copper winding followed by vacuum pressure impregnation for optimal dielectric strength and thermal resistance.

02. Dynamic Balancing

ISO 1940 Compliance

Rotor-impeller subassemblies undergo dual-plane electronic dynamic balancing to eliminate vibration and bearing fatigue.

03. 100% Routine Testing

Electrical & Dielectric Checks

Every unit passes high-voltage breakdown, insulation resistance, no-load current, and wattage checks prior to approval.

04. Airflow Validation

Pressure & CFM Verification

Performance curves are validated on calibrated wind tunnel test benches to verify airflow against backpressure ratings.

Technical FAQ

Frequently Asked Questions for OEM Buyers

Key technical considerations when selecting single inlet centrifugal blowers with external rotor motors.

The external rotor motor integrates the rotor directly into the blower impeller hub. This creates an exceptionally compact direct-drive unit without external motor shafts or couplings. The single inlet configuration provides targeted air intake ideal for pressurized enclosures, ducting, and tight equipment envelopes.
Single inlet blowers take in air from one side, producing high static pressure and a focused discharge ideal for ducted or filtered air paths. Double inlet blowers draw air from both sides to maximize total CFM volume in wider open plenum spaces with lower static resistance.
Yes. We design and wind motors specifically for global electrical standards, including 115V 60Hz (North America), 230V 50Hz (Europe/Asia), 400V 3-Phase, as well as customized EC wide-voltage drives.
Standard housings are fabricated from galvanized steel. Options include heavy epoxy powder coating, lightweight aluminum construction, or grade 304/316 stainless steel for corrosive environments.
Delco Fans Pvt. Ltd. was established in 1974. We have over 50 years of continuous in-house tooling, winding, dynamic balancing, assembly, and testing experience at our manufacturing plant in Wagle Industrial Estate, Thane, India.

Request Technical Specifications & OEM Product Catalog

Contact our engineering desk for custom drawings, torque-speed curves, airflow test reports, and volume pricing.

Get Catalog