Delco Fans Pvt. Ltd. (est. 1974) delivers industrial-grade centrifugal blowers, shaded pole motors, and fractional horsepower (FHP) gear assemblies engineered to withstand ambient operational temperatures up to 55°C, high dust loads, and continuous duty requirements across Dubai, Abu Dhabi, Sharjah, and the northern Emirates.
Designed for evaporative coolers and specialized fluid machinery requiring resilient starting torque and low thermal rise in warm climates.
Get a Quote
Permanent magnet micro synchronous motor delivering predictable slow-speed rotation for damper actuators and commercial fan drives.
Get a Quote
Heavy-duty squirrel cage induction motor with 100% pure copper windings for direct coupling to industrial centrifugal blower impellers.
Get a Quote
Compact fractional horsepower geared motor range engineered for packaging automation, conveyor drives, and air filter indexing systems.
Get a Quote
High-efficiency single-phase AC drive constructed for continuous operation in fluid pumps, ventilation blowers, and air handling skids.
Get a Quote
Robust capacitor-start motor ideal for commercial kitchen exhaust blowers, workshop machinery, and localized ventilation fans.
Get a Quote
Corrosion-resistant aluminum casing featuring superior heat dissipation, optimized for VFD variable speed centrifugal air movement.
Get a Quote
Ultra-low speed motor providing constant torque for HVAC fresh air louver control, automated valves, and industrial displays.
Get a QuoteSelecting industrial centrifugal blowers for export to the United Arab Emirates requires specialized aerodynamic and electrical engineering. Standard off-the-shelf air blowers designed for temperate European or Asian environments frequently experience premature thermal breakdown, bearing seizure, and severe flow rate reduction when subjected to Arabian Gulf ambient extremes.
Delco blowers destined for GCC deployment feature Class H insulation (180°C rated) with Class F thermal rise limits. Stator cores utilize high-grade silicon steel laminations to minimize eddy current losses during extreme peak ambient cycles.
Fine silica sand (PM10 and PM2.5 particulates common during UAE Haboob weather events) causes rapid abrasive wear on standard bearings. Our external rotor blowers utilize double-sealed IP55/IP66 bearing cavities with synthetic high-viscosity grease.
Coastal industrial zones in Dubai Maritime City, Jebel Ali Free Zone (JAFZA), and Mussafah require C5-M marine-grade powder-coated scroll housings and electro-galvanized forward/backward curved steel impellers.
Our custom AC FHP and three-phase direct-drive centrifugal blowers are specified by MEP contractors, equipment manufacturers, and facility management firms across the seven Emirates:
Locations: Downtown Dubai, Business Bay, Yas Island (Abu Dhabi).
Heavy-duty double-inlet centrifugal blowers operating against high static pressure (500 Pa to 1500 Pa) to purge moisture and heat from chiller mechanical rooms, ensuring continuous 24/7 refrigeration loop stability.
Locations: Ruwais Industrial Complex, Habshan, Fujairah Oil Zone.
Direct-coupled backward curved industrial exhaust fans built with spark-proof inlet cones and ATEX-certified motor interfaces for hazardous dust, VOCs, and hydrocarbon vapor filtration systems.
Locations: Hospitality sector (Palm Jumeirah hotels, Dubai Mall, Al Majaz Sharjah).
Single-inlet centrifugal fans with out-of-airstream motors (drain plug equipped scroll housings) designed to extract heavy grease fumes at 80°C+ without contaminating electrical windings.
Locations: Commercial towers in DIFC, Dubai Silicon Oasis, KIZAD Abu Dhabi.
High-efficiency forward curved centrifugal blowers providing constant air movement across multi-stage HEPA filters, cooling coils, and heat recovery wheels inside Fresh Air Handling Units (FAHUs).
Locations: Dubai Healthcare City, Sheikh Shakhbout Medical City.
Ultra-quiet customized EC (Electronically Commutated) centrifugal blowers engineered for precise pulse-width modulation speed control, maintaining exact positive/negative room pressure differential.
Locations: Al Ain, Ras Al Khaimah agricultural facilities.
Resilient single-phase MCP and YC series motors coupled with high-flow fans to push humid air through pad cooling systems, preserving commercial greenhouses during peak summer months.
Compare parameters for standard and custom air movement units engineered for UAE industrial and commercial supply.
| Blower / Motor Type | Airflow Range (CFM / m³/h) | Static Pressure (Pa) | Voltage / Freq (UAE Specs) | Impeller Geometry | Primary Industrial Fit |
|---|---|---|---|---|---|
| Single Inlet Centrifugal | 150 – 2,200 CFM | 120 – 650 Pa | 220V 50Hz / 400V 50Hz | Forward Curved (Galvanized Steel) | Cleanroom FFU, OEM Medical, Panel Cooling |
| Double Inlet Centrifugal | 800 – 5,500 CFM | 200 – 900 Pa | 220V / 380-415V 50Hz | Double Width Forward Curved | HVAC AHUs, FAHUs, Duct Boosters |
| Backward Curved Plug Fan | 500 – 8,000 CFM | 350 – 1,800 Pa | 380V - 415V 50Hz (3-Phase) | Backward Inclined (Non-Overloading) | Dust Collection, High-Resistance Filters |
| Tangential / Cross-Flow Blower | 80 – 450 CFM | 30 – 110 Pa | 110V / 220V 50/60Hz | Cylindrical Cross-Flow Wheel | Air Curtains, Slim FCU, Equipment Cooling |
| YE3 15kW 3-Phase AC Motor | Coupled Drive (up to 15,000 CFM) | System Dependent | 400V 50Hz (DEWA / ADDC Std) | Squirrel Cage Direct Drive | Heavy Industrial Blowers, Process Exhaust |
| Custom EC Centrifugal Blower | 200 – 3,800 CFM | 150 – 1,200 Pa | 200V - 277V 50/60Hz | Backward / Forward EC Motorized | Green Building Projects (Al Sa'fat / Estidama) |
The United Arab Emirates is aggressively advancing its sustainability targets under the UAE Net Zero by 2050 strategic initiative and the Dubai Clean Energy Strategy 2050. Municipal engineering standards in Dubai (Al Sa'fat Green Building System), Abu Dhabi (ESTIDAMA Pearl Rating System), and Ras Al Khaimah (Barjeel) have instituted strict energy performance coefficients for electrical drives and mechanical HVAC equipment.
Standard IE1 efficiency induction motors are being phased out across major commercial developments in UAE. Delco Fans supplies IE3 super-premium efficiency three-phase motors and direct-drive EC centrifugal blowers that consume up to 30% less electrical power during continuous year-round operation.
Modern HVAC systems in Dubai Silicon Oasis and Abu Dhabi Industrial City demand blowers capable of seamless modulation via Variable Frequency Drives (VFDs). Our inverter-duty rated copper coil motors withstand high voltage spikes ($\text{dV}/\text{dt}$) without insulation puncture.
Acoustic comfort regulations in urban residential towers and hospital zones limit maximum noise thresholds. Delco blowers undergo dynamic balancing to ISO 1940 Grade G2.5 standards, reducing vibration transmission and mechanical noise levels below 62 dBA.
With a manufacturing heritage originating in 1974 at our Thane (West) industrial plant in Maharashtra, India, Delco Fans Pvt. Ltd. combines over five decades of electro-mechanical expertise with specialized global export capabilities.
Unlike pure trading intermediaries, every fan motor, shaded pole drive, and centrifugal scroll is engineered, assembled, and load-tested inside our fully owned manufacturing facility.
Each production lot destined for Jebel Ali or Port Khalid undergoes dielectric high-pot tests, locked-rotor amp verification, dynamic balance checks, and no-load power audits.
We customize shaft lengths, keyway profiles, mounting flange dimensions, lead wire terminations, and impeller width ratios according to your exact CAD/STEP specifications.
Yes. All single-phase (220V/230V 50Hz) and three-phase (380V/400V/415V 50Hz) motors and blowers are manufactured to standard GCC utility voltages. We also provide dual-frequency 50Hz/60Hz coils for marine and export equipment.
We utilize Class H insulated copper magnetic wire, high-temp synthetic lubrication (rated up to 160°C), and oversized cooling fins. For direct-drive blowers, motor sizing is calculated with a 1.15 to 1.25 service factor to account for reduced thermal dissipation.
Shipments dispatched from Nhava Sheva (JNPT) Port in Mumbai reach Jebel Ali or Port Khalid within 4 to 6 days transit time. Standard OEM custom build times range between 2 to 4 weeks depending on batch volume.
Absolutely. We manufacture application-specific blower scroll housings, mounting brackets, and specialized wheel widths to fit tightly into non-standard mechanical cabinets or compact air handling units.
Housings receive multi-stage zinc phosphate pre-treatment followed by thermosetting epoxy polyester powder coating (C4/C5 corrosion class). Impellers can be supplied in 304/316 grade stainless steel or anodized aluminum.
Click the "Get a Quote" button on any product card or use the main quote request link below. Our engineering team will review your airflow (CFM), static pressure (Pa), voltage, and duty requirements to deliver complete technical datasheets.
Partner with a trusted manufacturer celebrating 50+ years of engineering excellence. Send us your duty point requirements (CFM, Static Pressure, Ambient Temp, Voltage) for fast dispatch to the United Arab Emirates.